Re: ORGLIST: Measurement of butadiene

Date view Thread view Subject view Author view Attachment view

From: Jacob Zabicky (zabicky$##$bgumail.bgu.ac.il)
Date: Fri Jun 01 2001 - 06:00:52 EDT


Hello Peter,

Perhaps start by adding some proton-free solvent to reduce volatility, a
marker if necessary, and run a proton NMR spectrum. Depending of the
relative concentration of other components, it shoudn't be difficult to
integrate the butadiene peaks relative to those of the marker.

All the best

Jacob

At 17:36 31/5/1, Hanson, Peter E. Hanson wrote:
>Hello,
>
>
>Can anyone suggest a method that can be used to measure stoichiometric
>amounts (~10 mL) of condensed 1,3-butadiene? I would be grateful for
>any and all feedback.
>
>
>Much thanks in advance,
>
>
>Pete Hanson
>
>--
>Dr. Peter E. Hanson
>Assistant Professor of Chemistry
>Wittenberg University
>P.O. Box 720
>Springfield, OH 45501-0720